Reactor seal lubrication cooling station
Technical Parameters
1, the working medium: ethylene glycol
2, pump outlet pressure: 0.2MPa
3, pump flow: 20 L / min (1.2 m3 / h)
4, medium temperature: supply temperature 45 ℃, return temperature 55 ℃
5, filter: two one with a preparation, filtration 120 mesh
6, the motor requirements: EXdT4